WT-RO-2000 Water Treatment and Reverse Osmosis

WT-RO-2000 water treatment and reverse osmosis system has been designed to turn raw water from ground or surface water into safe drinking water, capacity of 2000 liters per hour can be achieved, consisting of a sand filter to remove particulates, turbidity, sand and rust, an activated carbon filter to remove the chlorine, pesticides, herbicides, disinfectants, and VOCs which might otherwise damage the reverse osmosis membrane, a water softener to reduce hardness of water, a micro filter is required as a last step before the RO membranes to prevent any debris, sand particles or piping material to damage the membranes. The reverse osmosis process uses a semi-permeable membrane to separate and remove dissolved solids, organics, pyrogens, submicron collodial matter, viruses, and bacteria from water. The process is called “Reverse” Osmosis since it requires pressure to force pure water across a membrane, leaving the impurities behind. Reverse osmosis is capable of removing 95 – 99% of the total dissolved solids (TDS) and 99% of all bacteria, thus providing safe, pure water.

Technical route and flow diagram instructions

Raw water tank → Booster pump → Sand filter → Activated carbon filter → Softener Micro filter
→ High pressure pump → Reverse osmosis → Permeate tank

Key Features

Materials of Construction

Skid Frame: SS304

Membrane Elements:Hydraulics ESPA2-4040

Membrane Housings: SS304

Low pressure piping: SS304

High pressure piping: SS304

Pump and Motor

Pump: 304SS vertical multi-stage centrifugal

Motor: TEFC, 380/460 VAC, 3-phase, 50/60 Hz.

Standard Features

4” x 40” High rejection membrane elements

5-micron sediment pre-filter housing

Automatic inlet solenoid valve

PLC control

Product water conductivity monitor

Operating pressure gauges

Product and concentrate flow meters

Concentrate and recycle flow control valves

Low inlet pressure switch with shutdown alarm

Auto/Manual wash

Optional Equipment Available
Atmospheric storage tanks with level control and repressurization pump
Pressurized storage vessels
UV
Ozone generator
Membrane clean-in-place (CIP) systems
Pretreatment chemical injection systems

Technical Specifications

Model No  WT-RO-2000
Capacity 2000LPH(Liter per Hour)
Nominal Recovery  65-75%
Nominal Salt Rejection 99.60%
Operating Temperature 15°C-45°C
Design Temperature 25°C
Feed Pump 0.75KW
High Pressure Pump  2.2KW
Voltage 220V /380V/460V – 50Hz/60Hz